Computational Fluid Dynamics (CFD)
Golchehreh Shajari; Morteza Abbasi; Mehran Khaki Jamei
Abstract
In this study, comprehensive numerical simulations were conducted to examine laminar pulsatile developing flows through flat channels. The developing velocity fields and the hydrodynamic entry length were explored for the Reynolds numbers from 20 to 200, and the low and intermediate non-dimensional pulsation ...
Read More
In this study, comprehensive numerical simulations were conducted to examine laminar pulsatile developing flows through flat channels. The developing velocity fields and the hydrodynamic entry length were explored for the Reynolds numbers from 20 to 200, and the low and intermediate non-dimensional pulsation frequency or the Womersley number (1.08 ≤Wo≤ 8.86). For all simulations, the pulsating amplification factor was considered from zero to one, (0 ≤A≤ 1), and to achieve more practical and relevant outcomes, time-dependent parabolic inlet velocity profiles were applied. The outcomes reveal that for the higher values of the pulsation frequency or the Womersley number (6 ≤ Wo ≤ 8.66), the maximum pulsatile entranced length during a cycle is close to the inlet length of the mean component of the flow. On the other hand, for the rest of the Womersley number range (1.08 ≤ Wo < 6), and high amplification factor (0.5 ≤ A), the value of the entrance length increases and is significantly different from the development length of the steady component. Moreover, the results demonstrate that the entry length correlates with the Womersley number through a power-law function, whilst it has linear correlations with the Reynolds number and the amplification factor. Further, using the result of the accomplished numerical study, a practical correlation of the entrance length is offered to be used in the design phase for any type of pulsatile flow through the flat channels.
Biomechanics
Mehdi Jahangiri; Mohsen Saghafian; Mahmood Reza Sadeghi
Abstract
A numerical study of hemodynamic parameters of pulsatile blood flow is presented in a stenotic artery with A numerical study of hemodynamic parameters of pulsatile blood flow is presented in a stenotic artery with non-Newtonian models using ADINA. Blood flow was considered laminar, and the arterial ...
Read More
A numerical study of hemodynamic parameters of pulsatile blood flow is presented in a stenotic artery with A numerical study of hemodynamic parameters of pulsatile blood flow is presented in a stenotic artery with non-Newtonian models using ADINA. Blood flow was considered laminar, and the arterial wall was considered rigid. Studied stenosis severities were 30, 50, and 70% of the cross-sectional area of the artery. Six non-Newtonian models were used to model the non-Newtonian behavior of blood, and their results were compared with the Newtonian model. The results showed that in Power-law and Walburn-Schneck models, unlike other models, shear stress values before and after the stenosis were smaller than Newtonian models. Also, in maximum flow rate, the Carreua, generalized Power-law, Casson, and Carreua-Yasuda models showed a reduction in global importance factor of non-Newtonian behavior, and subsequently, the results approached Newtonian model. In minimum flow rate, the global importance factor of Newtonian behavior increased, which highlighted the importance of Newtonian model. In minimum flow rate, Carreua-Yasuda model was more sensitive to the non-Newtonian behavior of blood compared to Carreua, Casson, and Power-law models. Also, in that time period, Walburn-Schneck was less sensitive to the non-Newtonian behavior of blood. On the other hand, this model did not show sensitivity when the flow rate was at its peak. Power-law model overestimated the global importance factor values. Therefore, Power-law model was not suitable, because it showed extreme sensitivity to dimension. Walburn-Schneck model was not suitable too because it lacked sensitivity.